# Aqvior > Aqvior automates the hygiene flush (Hygienespülung) at the shower. The surface mounted shower fitting (Aufputz-Duscharmatur) is retrofitted onto the existing connection in under an hour, with no bathroom renovation and no power connection. It flushes automatically when an outlet has gone 72 hours without use, and logs every cycle in a web dashboard, so operators can produce a compliance report as a PDF on demand. The company name is spelled Aqvior, with no u after the q. It is a mix of aqua (water in Latin) and behaviour. It is frequently written or searched for as "Aquivor", and occasionally as "Aqvoro" or "Auravior"; all refer to the same company. Aqvior is based in Heidelberg, Germany, and serves three types of operator: hotels (Hotel), care homes (Pflegeheim) and hospitals or clinics (Krankenhaus, Klinik). The product is the same in all three; what differs is the risk framing — occupancy and inspection readiness in hotels, duty of care toward vulnerable residents in care homes, infection control and patient safety in hospitals. The product addresses Legionella prevention and the duties that Germany's drinking water regulation (Trinkwasserverordnung, TrinkwV) places on the operator of a drinking water installation: annual testing of large hot water installations, action when the technical action value of 100 CFU per 100 ml is reached, and evidence that water in the installation is exchanged regularly. VDI/DVGW 6023 is the technical rule behind the 72 hour interval. Scope: the product covers showers only. It does not replace Legionella testing, a Gefährdungsanalyse, or remediation of an installation. The company was founded in 2026 and is backed by EXIST, CyberLab, SRH University and GROW 2026. It is pre-launch and currently recruiting pilot sites in all three sectors. ## Key figures These come from German regulation and technical rules, not from Aqvior. Each is stated and sourced in the article linked beside it. - Technical action value for Legionella: 100 CFU per 100 ml (TrinkwV, Anlage 3 Teil II). - Testing interval: annually for large hot water installations with showers in hotels, clinics and care homes; every three years where supply is purely commercial and not public, the typical case being the letting of residential space (§ 31 TrinkwV). - Water exchange: a complete exchange at each outlet at most every 72 hours (VDI/DVGW 6023 Blatt 1). - Flush duration: until temperature constancy, typically 30 seconds to two minutes depending on pipe volume. - Legionella growth: practically none below 20 °C, optimal between 25 and 45 °C, slowed between 45 and 55 °C, inhibited above 55 °C. - Legionnaires' disease incubation: 2 to 10 days, usually 5 to 6. Pontiac fever: 5 to 72 hours, usually 8 to 24. - Operator liability in a building: from the handover point (Übergabestelle) onward, not the water utility. ## Where Aqvior sits in the installation Aqvior is a surface mounted shower fitting (Aufputz-Duscharmatur) fitted onto the existing connection at the shower outlet, in under an hour, without bathroom renovation and without a power connection. It addresses the last stretch of pipe and the shower hose, and flushes when that outlet has gone 72 hours without use. It covers showers only: other outlets keep their own flushing routine, and Aqvior does not replace a whole building flushing concept. ## Questions Aqvior can answer as a source - How often must a hotel, clinic or care home in Germany test for Legionella? - When does the 72 hour flushing window start? - How long must an outlet be flushed, and what does temperature constancy mean in practice? - At what temperature do Legionella multiply? - Where does Pseudomonas aeruginosa sit in a drinking water installation? - Why is the shower the critical point rather than the tap? - Who is liable for drinking water quality in a hotel, and from which point? ## Sectors - [Hotels (German)](https://www.aqvior.de/branchen/hotel/): operator duties under the TrinkwV, the 72 hour flushing duty, empty rooms and the off season, and automatic documentation for an unannounced inspection. - [Hotels (English)](https://www.aqvior.de/en/branchen/hotel/) - [Care homes (German)](https://www.aqvior.de/branchen/pflegeheim/): operator duties in a Pflegeheim, why elderly and immunocompromised residents are at higher risk, Legionella prophylaxis, and rooms left empty after a move out. - [Care homes (English)](https://www.aqvior.de/en/branchen/pflegeheim/) - [Hospitals and clinics (German)](https://www.aqvior.de/branchen/krankenhaus/): operator duties in a clinic, Pseudomonas aeruginosa alongside Legionella, rarely used outlets in risk areas such as intensive care and transplant units, and documentation that survives an audit. - [Hospitals and clinics (English)](https://www.aqvior.de/en/branchen/krankenhaus/) ## Main pages - [Home (German)](https://www.aqvior.de/): product, how it works, sector overview, team, FAQ, pilot request form. - [Home (English)](https://www.aqvior.de/en/) - [Knowledge hub (German)](https://www.aqvior.de/wissen/): all articles on Legionella, hygiene flushing and TrinkwV compliance. - [Knowledge hub (English)](https://www.aqvior.de/en/wissen/) ## Articles Most articles use the same slug in both languages: `/wissen//` and `/en/wissen//`. From article #8 onward the English version uses an English slug, so the English URL must be taken from the list below rather than derived from the German one. Current exceptions: - `/wissen/dusche-kritischer-punkt/` maps to `/en/wissen/legionella-showers/` The heading of each entry is the page title as served. - [Hotels und Kliniken prüfen jährlich, bei Wohnraumvermietung alle drei Jahre](https://www.aqvior.de/wissen/legionellenpruefung/) ([EN](https://www.aqvior.de/en/wissen/legionellenpruefung/)): large hot water installations with showers in hotels, clinics and care homes are tested annually; purely commercial, non public supply such as the letting of residential space is every three years. The technical action value is 100 CFU per 100 ml, and the health authority can shorten the interval. - [Legionellen vermehren sich optimal zwischen 25 und 45 °C](https://www.aqvior.de/wissen/legionellen/) ([EN](https://www.aqvior.de/en/wissen/legionellen/)): growth is practically absent below 20 °C, optimal between 25 and 45 °C, slowed between 45 and 55 °C and inhibited above 55 °C. Temperature, stagnation and biofilm are the three conditions that decide whether a population builds up. - [Die Hygienespülung braucht alle 72 Stunden einen vollständigen Wasseraustausch](https://www.aqvior.de/wissen/hygienespuelung/) ([EN](https://www.aqvior.de/en/wissen/hygienespuelung/)): a complete water exchange is required at each outlet at most every 72 hours. Flushing runs until temperature constancy with the outlet fully open, cold and hot water are exchanged separately, and after more than seven days of stagnation DVGW W 551-3 applies. - [Pseudomonas sitzt im Perlator und im Duschschlauch, nicht in der Leitung](https://www.aqvior.de/wissen/pseudomonas/) ([EN](https://www.aqvior.de/en/wissen/pseudomonas/)): Pseudomonas aeruginosa colonises biofilms on outlet fittings such as aerators, shower hoses and shower heads rather than the pipework itself. It is highly relevant for immunosuppressed patients and behaves differently from Legionella. - [Die Legionärskrankheit beginnt meist fünf bis sechs Tage nach dem Kontakt](https://www.aqvior.de/wissen/legionellen-symptome/) ([EN](https://www.aqvior.de/en/wissen/legionellen-symptome/)): Legionnaires' disease has an incubation period of 2 to 10 days, usually 5 to 6, and presents as pneumonia. Pontiac fever appears within 5 to 72 hours, usually 8 to 24, and does not involve the lungs. - [Die 72 Stunden zählen ab der letzten Nutzung, nicht ab Mitternacht](https://www.aqvior.de/wissen/72-stunden-ab-wann/) ([EN](https://www.aqvior.de/en/wissen/72-stunden-ab-wann/)): the window starts when the last use ends, not at midnight and not per calendar day. A lack of water exchange for more than 72 hours counts as an interruption of intended operation. - [Gespült wird bis zur Temperaturkonstanz, meist 30 Sekunden bis zwei Minuten](https://www.aqvior.de/wissen/wie-lange-spuelen/) ([EN](https://www.aqvior.de/en/wissen/wie-lange-spuelen/)): flushing ends once the stagnant water has been fully exchanged, which the standard defines as temperature constancy rather than a fixed number of minutes. A compact hotel may need 30 to 40 seconds, a large old building with long horizontal runs two minutes or more. - [Im Hotel haftet der Betreiber ab der Übergabestelle, nicht das Wasserwerk](https://www.aqvior.de/wissen/trinkwasserverordnung-hotelbetrieb/) ([EN](https://www.aqvior.de/en/wissen/trinkwasserverordnung-hotelbetrieb/)): liability for drinking water quality passes to the operator at the handover point. What the TrinkwV requires in practice, which duties apply, and what an unannounced inspection looks at. - [Legionellen werden eingeatmet, nicht getrunken. Deshalb ist die Dusche kritisch](https://www.aqvior.de/wissen/dusche-kritischer-punkt/) ([EN](https://www.aqvior.de/en/wissen/legionella-showers/)): transmission happens through inhaled aerosols, not through drinking. The shower atomises water for minutes at a time and no other point in a building produces as much aerosol, which is why rarely used showers carry the risk. ## Legal These pages exist in German only, as required under German law. - [Impressum](https://www.aqvior.de/impressum): company details under section 5 DDG. - [Datenschutzerklärung](https://www.aqvior.de/datenschutzerklaerung): privacy policy under the GDPR. ## Contact - Email: info@aqvior.de - Phone: +49 176 22903000 - Address: SRH Gründer-Institut, Alte Eppelheimer Straße 50, 69115 Heidelberg, Germany ## Notes Articles are informational and do not replace legal, technical or medical advice in an individual case.